Products
  • Products
  • Suppliers
  • Buyers
  • Exhibitors
Search
Products
  • Products
  • Suppliers
  • Buyers
  • Exhibitors
Search
Products News Exhibitions Exhibitors
Ceiling Suspended Exposed fan coil unit water cooled chiller central air conditioning solution for industrial factory workshop Ceiling Suspended Exposed fan coil unit water cooled chiller central air conditioning solution for industrial factory workshop Ceiling Suspended Exposed fan coil unit water cooled chiller central air conditioning solution for industrial factory workshop Ceiling Suspended Exposed fan coil unit water cooled chiller central air conditioning solution for industrial factory workshop Ceiling Suspended Exposed fan coil unit water cooled chiller central air conditioning solution for industrial factory workshop

Ceiling Suspended Exposed fan coil unit water cooled chiller central air conditioning solution for industrial factory workshop

FOB Price:
USD 100-102 / Bag
Min.Order Quantity:
1 Bag
Supply Ability:
500000 Twenty-Foot Container per Day
Port:
Tinajin
Place of Origin:
chain
Payment Terms:
L/C, T/T, PayPal
Brand:
YESNCER
Products Model:
FP136
Share:
  • Products Details
  • Company Profile

Quick Details

  • Brand Name: YESNCER

    Model Number: FP136

    Place of Origin: chain

Packaging & Delivery

  • Packaging Details: Wooden box packaging / carton packaging
  • Delivery Detail: 3 Days

Specifications

2 - 99 pieces

CN¥1,062.64

100 - 499 pieces

CN¥914.79

>= 500 pieces

CN¥812.09

Benefits:
US $500 couponsClaim now

pieces

CN¥870.36/pieceMin. order : 1 pieceGet samples

 

Lead time:

Quantity (pieces) 1 - 2 3 - 100 101 - 500 > 500
Lead time (days) 15 25 35 To be negotiated

Customized logo(Min. order 100 pieces)

Customized packaging(Min. order 100 pieces)

Graphic customization(Min. order 100 pieces)

 

 

 

Purchase details

Protection with

Shipping:

Contact supplier to negotiate shipping details

Enjoy On-time Dispatch Guarantee

Payments:

···

Enjoy encrypted and secure payments View details

Returns & Refunds

 

 

Overview

Essential details

After-sales Service Provided:

Free spare parts

Warranty:

3 years

Application:

Hotel, Commercial, Household

Power Source:

Electric

App-Controlled:

NO

Place of Origin:

Hebei, China

Brand Name:

KDGD

Model Number:

KDGD FP-68

Material:

Steel mold and ABS

Certificate:

CE, CRAA, ISO, CCC, TUV

Type:

exposed Fan coil unit + water cooled chiller

Solution:

central air conditioning

Installation:

Standing or wall mounted

Voltage:

220-230V/50HZ

Power:

62w

Volume:

680m3/h+

Cooling capacity:

3.6kw/h+

Heating capacity:

5.4kw/h+

Packaging & delivery

Packaging Details
inner packing: plastic foam or plastic bag
Outer packing:carton, pallat or wooden case
Port
Tianjin port or other you want
Picture Example:

package-img

package-img

Lead time:
Quantity(pieces) 1 - 2 3 - 100 101 - 500 >500
Lead time (days) 15 25 35 To be negotiated

Ceiling Suspended Exposed fan coil unit water cooled chiller central air conditioning solution for industrial factory workshop

 

Project Overview
 

Project Name: Casting Machine Processing

Total construction area: 12000 m2

Room type: steel structure workshop

Wall body: color steel composite plate

Heating area: 12000 m2

Refrigeration use area: 12000 m2

Demand for work and energy: cooling in summer and heating in winter

Heat source equipment: water chiller

End system equipment: universal exposed fan coil unit

 

Design Ideas

 

The foundry group mainly provides precision machines and parts processing and casting for various countries, so the workshop has high requirements on environmental temperature, and the parts processing equipment-CNC machine tools have strict requirements on environmental temperature, which is too high to run normally. In addition, it is necessary to save operating costs. According to the adjustment of national energy policy and the requirements for environmental protection, the use of clean, energy-saving and efficient new energy is the main policy of the country for a long time to come. In order to meet the special requirements of workshop temperature and respond to the call of national policy, the engineers considered comprehensively that the main engine selected water chiller, and the terminal equipment matched with universal exposed floor standing or ceiling suspended fan coil unit, which not only met the special temperature requirements of processing precision machine tools, but also saved costs for production enterprises.

Ceiling Suspended Exposed fan coil unit water cooled chiller central air conditioning solution for industrial factory workshop

In this scheme, electric power is used as the clean energy source for cooling and heating. By consuming a small amount of electric energy, the low-grade heat energy in the atmosphere is converted to high-grade heat energy, and the water chiller is used to prepare cold water and hot water for cooling and heating of buildings. The utilization of this new energy can completely replace the municipal central heating and any heating methods such as coal, oil, gas and electric heating, and it can also refrigerate in summer, which greatly reduces the investment, and is not affected by the ambient temperature and does not need auxiliary electric heating. The system has strong stability, high reliability, good heating effect, environmental protection and no pollution, and no special person is needed to manage it. Under the normal working conditions of the terminal pipe network and the radiator, the indoor temperature reaches or exceeds the standard specified.
 

Calculation Parameters
 
1. Calculation parameters of outdoor design in winter

Seasonal parameters Average minimum temperature Extremely cold minimum temperature Relative humidity% Outdoor average wind speed (m/s) Atmospheric pressure  KPa
winter -7 -15 55 1.5 102

 
2. Calculation parameters of outdoor design in summer

Seasonal parameters Average minimum temperature maximum temperature Relative humidity% Outdoor average wind speed (m/s) Atmospheric pressure  KPa
summer 27 34 55 1.5 102


 

Cooling and heating load calculation

Ceiling Suspended Exposed fan coil unit water cooled chiller central air conditioning solution for industrial factory workshop

Selection of water chiller, according to the Design Manual of Heating, Ventilation and Air Conditioning, the cooling and heating heat load consists of the basic cooling/heat consumption of the outer envelope and the inner envelope and its additional cooling/heat consumption and cold air infiltration cooling/heat consumption. According to the outdoor temperature parameters, the unit cooling load index is 110W/m2, and the unit heat load index is 100W/m2.
 

1. determination of cooling load;

            Q1=12000×110×=1320kw

According to the characteristics of buildings and climatic conditions, the rated cooling capacity of water chiller with refrigeration configuration should be ≥1320kw to meet the use requirements.
 

2. determination of heat load;

            Q2=12000×100=1200kw

According to the characteristics of buildings and climatic conditions, the rated heat of water chiller for heating should be ≥1200kw to meet the use requirements.

 

System principle

 Ceiling Suspended Exposed fan coil unit water cooled chiller central air conditioning solution for industrial factory workshop

 

Water chiller absorbs a large amount of heat energy in circulating water through very little electric energy, which is compressed by compressor and changed into high-temperature heat energy. The water is transferred to heat the water, and the hot water is used for heating through fan coil unit, which can also provide cooling in summer.

 

Environmental protection and energy saving

The power of heating is the heat energy of circulating water, which only needs to consume a little power when absorbing the heat energy of circulating water, and the thermal efficiency is as high as 520%-780%. Compared with traditional energy sources, it not only has high thermal efficiency, but also avoids the emission of pollutants caused by the use of chemical energy, thus achieving the dual effects of energy conservation and environmental protection. The space is cooled and heated by fan coil unit, which runs as a whole and automatically adjusts the temperature, making the operation more stable and energy-saving.

 

Safe and reliable

By adopting physical working method, no toxic gas will be produced during the whole heating process, and no leakage accident will occur during the separation of water and electricity.

 

Low temperature operation

Not affected by the environment, it can be used all the year round. Whether in rainy days or cold winter, the intelligent control of heat pump unit can save manpower investment and ensure all-weather synthesis of high-temperature heat source.

 

 

 

 

 

 
  • Email to this supplier
  • To :
    YESNCER Fan Coil  |  Baoding Yuexin Cooling and Heating Equipment Manufacturing Co., Ltd.
  • *Subject :
  • Quantity Order:
  • *Message :

  • Your message must be between 20-2000 characters
  • + Add attachments :
    Select File  (Max 2 files) 
  •  Please enter your company name:

    Please make sure your company name is entered correctly.

  • * Please enter your email address:

    Please make sure your email address is entered correctly.

  • * Please enter your mobile phone:

    (+)   - 

    Please make sure your mobile phone is entered correctly.

Verified Supplier - Baoding Yuexin Cooling and Heating Equipment Manufacturing Co., Ltd. Bussiness Type:  Manufacturer
Scale:  501 - 1000 People
Country/Region:  China (Mainland)/Asia
Established:  2019
You May Like:
<font color='red'>Factory</font> Direct Supplier <font color='red'>Air</font> <font color='red'>Cooled</font> <font color='red'>Industrial</font> <font color='red'>Water</font> <font color='red'>Cooled</font> <font color='red'>Chiller</font>

<font color='red'>Fan</font> <font color='red'>Coil</font> <font color='red'>Unit</font> QWCR

<font color='red'>Fan</font> <font color='red'>Coil</font> <font color='red'>Unit</font> floor mounted

<font color='red'>Fan</font> <font color='red'>Coil</font> <font color='red'>Unit</font> CASSETTE TYPE

<font color='red'>Fan</font> <font color='red'>Coil</font> <font color='red'>Unit</font> wall mounted

Coolsour <font color='red'>Industrial</font> <font color='red'>Air</font> <font color='red'>Cooled</font> <font color='red'>Water</font> <font color='red'>Chiller</font>

Coolsour <font color='red'>Water</font> <font color='red'>Cooled</font> <font color='red'>Chiller</font> for <font color='red'>Central</font> <font color='red'>Air</font> Conditioner

<font color='red'>air</font> <font color='red'>conditioning</font> <font color='red'>fan</font> <font color='red'>coil</font> <font color='red'>unit</font>